Common Operation Trouble and Troubleshooting Method of Injection Molding Machine

General common operation troubles and troubleshooting methods are shown in following form according to repair experience of our company for reference.

TroublePossible reasonTroubleshooting method
Motor of oil pump rotates without pressure.Reverse rotation of motorExchanging any 2 phases among three-phase wires.
Deficient hydraulic oil and entry into airInject hydraulic oil to be higher than oil level line. Start up motor again after 1 to 3 hours after injecting oil into oil tank.
Dirty hydraulic oil and oil filterClean oil filter
Broken oil pump or severe internal oil leakageRepair or exchange
Loose or broken proportional valve or coil burnoutCheck power supply for coil of proportional pressure valve
Jammed proportional valve core or oil openingClean proportional valve
Oil & gas leakage of tube connectorsTighten tube connectors
 
Die closing impossibilityLoose & broken or damaged stroke switch wiring of safety doorConnect electric wires or replace switches.
Top pin has not retreated to original position.Check if top pin operates normally or not.
Loose & broken wires of die closing electromagnetic valve or broken coilsConnector or replace wires
Jammed oil opening of die closing electromagnetic valve or jammed valve coreClean direction valve
 
Injection failureUnclosed injection protection door or abnormal switch operationClose protection door or inspect stroke switch
Super-low injection pressureIncrease injection pressure
Super-low injection temperatureTo increase set temperature and check if electric heating ring is burnt out or broken or not for temperature rise failure.
Loose & broken injection electromagnetic valve wiring or broken coilsInspect wiring or replace electromagnetic valve
Jammed injection electromagnetic valve core or oil openingClean or replace electromagnetic valve
 
Screw rod can rotate but it will not feed.Without materials in hopperFeed materials into hopper
Damaged back pressure valve or improper pressure regulation due to super-high pre-molding retreating pressureReduce pressure of pre-molding back pressure valve or replace it
Jammed plastic entry into screw rod due to super-high temperature due to insufficient cooling water supplyIncrease cooling water flow and take out bonded lump
 
Movement failure of injection supportImproper position of movable limit stroke switch of injection supportAdjust position of stroke switch
Loose & broken electromagnetic valve wiring of injection support or broken coilsInspect wiring or replace electromagnetic valve
Jammed electromagnetic valve core or oil opening of injection supportClean or replace electromagnetic valve
 
Super-high temperature of hydraulic oilInsufficient hydraulic oilSupplement hydraulic oil
Insufficient water supply of cooling systemInspect and adjust cooling water flow
Super-high pressure of oil pumpRegulate to pressure required for products
Damaged oil pump or improper viscosity of hydraulic oilInspect oil pump and quality
 
Normal operation mode and failure of semi-automatic modeOperation cycle of injection molding machine is shown in Figure 1-3 of Chapter 1. Conversion within various phases is determined by 3 modes: 1) stroke switch; 2) electronic scale; 3) timer; Therefore, such electric appliances will not issue electrical signals for semi-automatic cycle failure.Determine power failure during the phase then find out corresponding control elements according to “operation cycle diagram” for solutions.
 
Failure of automatic modeFailure of electric eye, spotlight or loose screwInspect electric eye
Failure or damage of timing systemInspect and adjust timing system
Damaged heating ringInspect and replace
Poor thermocouple wiring or damageInspect and repair