Lubrication Distributors and Divider Blocks for Injection Molding Machines
A healthy lubrication pump cannot protect the machine if a divider block is blocked, leaking, incorrectly sized, or unable to meter lubricant to every point. Lubrication distributors divide and meter grease or oil from the main pump into controlled quantities for toggle pins, bushes, guides, bearings, ejector mechanisms, and other moving components. DAYA supplies progressive divider blocks, injector-type metering units, resistance distributors, fittings, and complete centralized-lubrication assemblies.

1. Deliver the Correct Lubricant Quantity to Every Lubrication Point
The distributor is the hydraulic logic element of a centralized lubrication system. Its internal pistons, injectors, or fixed restrictions determine how much lubricant reaches each branch and whether one blocked point interrupts or hides the rest of the cycle.
Common brands and machine applications we can support include:
SKF/Lincoln, Bijur Delimon, DropsA, ILC and Groeneveld-BEKA formats
Showa, Chen Ying, Yu-Han and common Asian lubrication components
OEM blocks used on DAYA, Haitian, Yizumi, Chen Hsong, Borche and LK machines
Custom assemblies with matched metering elements, outlets, fittings, tubing, and sensors
Compatibility is confirmed from the original model and application data. Brand names are used for identification and do not imply that parts with a similar appearance are automatically interchangeable.
2. Main Types, Configurations, and Selection Points
The correct configuration depends on the machine circuit and operating duty. The table below summarizes the most common options.
| Type / Configuration | Typical Application | Critical Selection Details |
|---|---|---|
| Progressive divider block | Sequential grease delivery with cycle monitoring | Section output, outlet combination, pressure |
| Injector/metering unit | Independent measured discharge at each point | Discharge volume, reset pressure, lubricant |
| Resistance distributor | Simple oil lubrication with calibrated restrictions | Resistance ratio, viscosity, flow |
| Manifold assembly | Compact distribution and organized tubing | Circuit map, ports, bracket, sensors |
Selection note: Never rely only on the front appearance or a shortened model number. Small differences in voltage, signal logic, pressure, flow, connector, dimensions, firmware, or material can prevent installation or create a new fault.
3. When Replacement or Technical Inspection Is Needed
A replacement should be considered when one or more of the following conditions are confirmed:
One or more lubrication points remain dry while the pump operates
Main-line pressure rises rapidly because a block or downstream line is obstructed
Distributor leaks around section seals, plugs, fittings, or outlet threads
Cycle indicator does not move or proximity feedback is missing
Incorrect metering causes excess grease at some points and starvation at others
Before replacing the component, verify the surrounding circuit. Wiring, connectors, power quality, contamination, cooling, lubrication, mechanical alignment, controller parameters, and downstream loads can produce the same symptom. Correct diagnosis avoids repeated failure of the new part.
4. How to Identify the Correct Replacement
For a fast and accurate quotation, please provide the following information:
1. Distributor brand/model, system type, section count, and total number of outlets
2. Metering volume or outlet ratio for every lubrication point
3. Inlet/outlet thread, tubing size, pressure, lubricant type and NLGI grade/viscosity
4. Cycle indicator or sensor details and PLC monitoring requirements
5. Photos showing port labels and tubing arrangement plus the machine lubrication diagram
If the nameplate is missing or unreadable, send multiple high-resolution photos with a ruler beside the component, mark every connector and port, and provide the machine brand, model, serial number, year, and the function controlled by the part.
5. Supply, Compatibility, and Service Options
We reproduce the outlet map and metering arrangement so each machine point receives the intended quantity. Replacement can include the complete block, individual sections, metering units, fittings, tubing, plugs, sensors, and mounting hardware.
Original or OEM-specified replacement when the exact part remains available.
Compatible industrial replacement after mechanical, electrical, hydraulic, and control details are checked.
Repair or refurbishment assessment for selected high-value components.
Matched upgrade solution when the original model is obsolete or repeatedly unreliable.
Where useful, we can supply related cables, connectors, sockets, seals, fittings, brackets, filters, sensors, or installation accessories together to reduce downtime caused by missing small parts.
6. Frequently Asked Questions
Can two outlets of a progressive divider be combined?
Some designs allow adjacent outlets to be combined, but the manufacturer’s bridging method and section rules must be followed. Incorrect plugging can stop the entire system.
How is a blocked lubrication point located?
Disconnect and test branches systematically while monitoring cycle indication and pressure. Do not simply raise pump pressure, because hardened grease or a blocked passage can damage lines and seals.
7. Request a Fast Parts Quotation
Send the original part model, clear nameplate photos, machine information, dimensions, and fault description. DAYA will review the application and recommend the most practical route: an exact replacement, a compatible alternative, repair support, or a coordinated upgrade.
Explore our injection molding machine spare parts and consumables, review more maintenance and troubleshooting resources, or contact DAYA for a quotation.
Reduce troubleshooting time and avoid an incorrect replacement—send us the part photos and machine details today.